Pompes JAPY | II 2 G Ex ia IIB T4 Gb | Zone 2 | ||
Calibratable digital turbine meter for diesel, gasoline and kerosene for installation in ATEX zones
Main features :
Can be installed in-line, at the end of the delivery hose, or directly on the gun.
Rugged body and sealed electronic board.
Microprocessor powered by 2 long-life batteries.
Reversible meter.
Materials in contact with the liquid: aluminum, polybutylene terephthalate, ceramic.
Adjustable display
Accuracy: ± 1% within flow range
Repeatability: 0.2
Flow rate: 7 to 120 l/mn
Maximum pressure: 20 bar
Pressure drop: < 0.03 bar (120 l/mn with diesel)
Operating temperature: -10°C to +50°C
Weight: 0.50 kg